An I section girder as shown in figure below simply supported over a span of a metres carries a uniformly distributed load of 100 kN/m over the entire span. The beam is strengthened by the addition of 15 mm thick flanges, wherever necessary Determine the length and width of the flange plates such that maximum stress due to bending does not exceed 125 MN/m²