Water at 10° C flows from a large reservoir by a 3cm diameter, 30m long horizontal pipe. Determine the discharge rate of water through the pipe and find the flow type in the tube. Consider all losses and take the value of f = 0.008 (p = 1000kg/m3), g = 9.81 m/s2 η = 1.138x10^-5 kg/m.s) From Large reservoir to pipe h = 22m, from smaller reservoir to pipe is 10m.