A confined aquifer has a source of recharge. K for the aquifer is 1.6 m/day. The water level in two wells of 2km apart is 60 m and 54 m respectively. The average thickness of the aquifer is 28m and the average width of aquifer is 6 km. Calculate the flow rate, darcy‘s velocity and the average linear velocity, if the effective porosity is 0.25