Consider a steam power plant operating on the ideal reheat Rankine cycle shown in figure 1 and 2. Steam
enters the high-pressure turbine at 15 MPa and 600°C and is condensed in the condenser at a pressure of
P1=21 KPa. If the moisture content of the steam at the exit of the low-pressure turbine is not to exceed 10.4
percent. Assume the steam is reheated to the inlet temperature of the high-pressure turbine.